What is different about the new Radiacode 103G? : r/Radiacode - Reddit
Mar 23, 2024 · The G has a higher resolution. Specially compared to the 102. The crystal is a gagg which means Gadolinium Gallium Garnet. That's why it also is plus 200.-€. 580.-€ still is cheap when …
Radiacode 102 vs 103 who's better : r/Radiation - Reddit
Dec 12, 2023 · I've seen this 1st image on this group and after buying the 102 just before the 103 came out I decided to get the newer one, too. To see the difference in accuracy and resolution I put a …
What do you find is a typical CPM background reading for Radiacode …
Sep 27, 2023 · I'm thinking about the Radiacode 102, although I don't really have a specific need for it. I used scintillator detectors before in my college physics lab, and having an energy spectrum …
Radiacode - Reddit
Is the maximum KeV that the radiacode 102 detect 2922? On both the android and pc versions of the radiacode program, I cannot scroll past 2922 KeV on the graph. Is this intentional and the maximum …
New release of Radiacode Windows application : r/Radiacode - Reddit
Nov 27, 2023 · Radiacode suggests using the Th family peaks to do this, via thoriated tungsten TIG electrodes. They've also provided a very nice video tutorial on their site. It is equally possible to do a …
Radiacode 101 Spectrometry for beginners. : r/Radiation - Reddit
Jan 11, 2022 · Radiacode 101 Spectrometry for beginners. I was hoping someone could point me in the right direction. I just received the radiacode 101 and I'm interested in testing my minerals, glass, …
Comparing gamma spectrometers RadiaCode 102 and MEASALL …
Oct 30, 2023 · Radiacode claims that the resolution of the Model 102 falls between 10% and 9% for cesium-137, which seems to be accurate, as my Radiacode has a resolution of 9.4% for cesium-137.
New Radiacode 103 with 8.2% ±0.4% FWHM released! : r/Radiation
Nov 27, 2023 · 15 votes, 28 comments. Radiacode just released Radiacode 103 with FHWM at 8.2% ±0.4% vs 9.5% in previous model (102)…
Tinkering with the Radiacode-101 : r/Radioactive_Rocks - Reddit
Dec 3, 2021 · The first reading is with the Radiacode 101 inserted backwards (unshielded) so it had the same elevation and distance from my sample (thorium mantle in glass jar) as it would in the shielded …
Raysid (<7% model) vs. Radiacode 102 Spectra comparison for Lu
Nov 27, 2023 · For Radiacode 102, two of crystals were placed on top and 2 crystals on the bottom side right over the center of the detector crystal due to the small size of the CsI (Tl) crystal Spectra …